• Another Person @lemmy.worldOP
    link
    fedilink
    English
    arrow-up
    10
    ·
    edit-2
    11 months ago

    What’s an expansion tank? I set it up like the old one was set up. All I did was disconnect the old one and reconnect the new one to the same pipes coming out of the wall.

    • rockSlayer@lemmy.world
      link
      fedilink
      arrow-up
      8
      arrow-down
      3
      ·
      edit-2
      11 months ago

      An expansion tank is necessary for water heaters, because the process of heating water causes it to expand. Without an expansion tank, pressure could build to unsafe levels

      • SpeakinTelnet@sh.itjust.works
        link
        fedilink
        arrow-up
        17
        ·
        11 months ago

        All tanks are equipped with a safety release for the pressure and the only time when that delta in pressure can be problematic is when you go from completely cold to hot due to the higher amount of water that can fit in the tank at lower temp.

        Otherwise I’ve never seen a house in Canada with an extension tank attached to the water heater and the water come in ice cold in the winter.

      • falsem@kbin.social
        link
        fedilink
        arrow-up
        11
        ·
        11 months ago

        Pressure won’t build up, it will be let out by the pressure relief valve and make a mess on the floor. Which is also undesirable.

        • SheeEttin@lemmy.world
          link
          fedilink
          English
          arrow-up
          2
          arrow-down
          1
          ·
          11 months ago

          Well, right up until the pressure relief valve fails. Whether it fails open or closed, you’re gonna have a bad time, because either way you’re probably going to have a lot of water where there’s not supposed to be water.

      • Another Person @lemmy.worldOP
        link
        fedilink
        English
        arrow-up
        3
        ·
        edit-2
        11 months ago

        In reading it looks like it is for homes newer than 1986? Our old water heater was 20 years old and we never had any issues with the pressure getting too high.

        • nowwhatnapster@lemmy.world
          link
          fedilink
          arrow-up
          2
          ·
          11 months ago

          If you are on municipal water and there is no check valve between you and the water meter then the municipal water supply is acting as the expansion tank. It may not be to code in your area but that’s how many homes were built in the past.

        • rockSlayer@lemmy.world
          link
          fedilink
          arrow-up
          1
          ·
          11 months ago

          Honestly, I don’t know, I’m not a plumber. There are a couple possibilities, including that it was built into the water heater or the relief valve did it’s thing. Some water heaters don’t need expansion tanks at all, either. It’s generally a “just in case” thing, since the right failures in the wrong way could lead to a hot water bomb going off in your house.